MODEL

CYLOS DR-T

PACING MODESMultimodes capability
MEASUREMENTS, HXWXMAX THICKNESS,MM52 x 50 x 6
WEIGHT, g31
Type (CONFIGURATION)Unipolar/bipolar
TELEMETRYYes
Real-time data
Egm (Real-time data)Yes
Battery status (Real-time data)Yes
Programmed setting (Real-time data)Yes
Lead impedance (Real-time data)Yes
Trending data
Pacing events (Trending data)Yes
Lead impedance (Real-time data)Yes
Rate histograms (Trending data)Yes
High-rate episodes (Trending data)Yes
Egm storage (Trending data)Yes
Energy capacity, ampere-hours (Trending data)1.3
Longevity, years  (Trending data)5.5 (at 3.6 V, 0.4 ms, 60 ppm, 500 Ω)
PROGRAMMER (Trending data)EPR 1000/ICS 3000
RANGE,PPM (Trending data)30-88 (increments of 1), 88-122 (increments of 2), 122-140 (increments of 3), 140-180 (increments of 5)
RATE HYSTERESIS (Trending data)Yes
REFRACTORY PERIOD, msec200-775 atrial; 250, 300, 350, 500 ventricular
RATE MODULATION (Trending data)Yes
Sensor type (Trending data)Accelerometer, closed-loop stimulator
PULSE AMPLITUDE, V (Trending data)Atrium: 0.1-4.8 (increments of 0.1), 4.8-8.4 (increments of 0.6); ventricule: 4.8-8.4 (increments of 0.2)
PULSE WIDTH, msec0.1, 0.2, 0.3, 0.4, 0.5, 0.75, 1, 1.5
Sensitivity, mvMulti possibilities0.1-7.5 atrial, 0.5-7.5 ventricular
Test signal (Trending data)15 ms sine squared atrial; 40 ms sine squared ventricular
CONNECTOR MEAS., MM (Trending data)IS-1
OTHER SPECIFICATIONS (AIR SUPPLY)Closed-loop stimulation (CLS); automatic mode conversion; night program; external pulse control up to 800 ppm; 2-channel IEGM with event marker; sensor test trend with complete rate forecast; assisted follow-up; AV delay; activity report; event counter; t
FDA CLEARANCE (Interference compensation)Yes
CE MARK (MDD) (Interference compensation)Yes
MARKETING REGION (Interference compensation)Worldwide
თქვენ შესაძლებელია აგრეთვე დაინტერესებული იყოთ მწარმოებლის შემდეგი ტექნიკური მახასიათებლებით:
პასუხისმგებლობის შეზღუდვა
ამ გვერდზე არსებული ინფორმაცია შესაძლებელია იყოს არასრული, მოიცავდეს გარკვეულ შეცდომებს ან არაზუსტ ინფორმაციას.
MedWOW იხსნის ყოველგვარ პასუხისმგებლობას და ვალდებულებას ამ გვერდზე განთავსებულ ნებისმიერ ინფორმაციაზე.

კარდიოსტიმულატორი, Biotronik, CYLOS DR-T
View More Items